Case 1
故障现象
Load Warning from library definition file "D:\Serdes\exercise\FILTER_wrk\lib.defs".
Unable to open library muRataLibWeb_tech at path C:\Users\Administrator\Desktop\ADS2011\murata_lib_ads2011later_521e\./muRataLibWeb_tech: Invalid Lib Path.
![](https://img.laitimes.com/img/__Qf2AjLwojIjJCLyojI0JCLiAzNfRHLGZkRGZkRfJ3bs92YsYTMfVmepNHL9gzViBnTYlld4dkYshmMMBjVtJWd0ckW65UbM5WOHJWa5kHT20ESjBjUIF2X0hXZ0xCMx81dvRWYoNHLrdEZwZ1Rh5WNXp1bwNjW1ZUba9VZwlHdssmch1mclRXY39CXldWYtlWPzNXZj9mcw1ycz9WL49zZuBnL3QzM4ADNxITM1ATNwEjMwIzLc52YucWbp5GZzNmLn9Gbi1yZtl2Lc9CX6MHc0RHaiojIsJye.png)
解决方法: 点击Yes
发现问题所在---红色字体“muRataLibWeb_tech”文件夹没有找到:
出错时原始的文件夹目录确实缺少红色字体文件:
新的文件列表—补充了箭头所指的文件夹;
重新打开ADS软件的这个工程,不再出现错误提示;
Case 2
故障现象 Error detected by hpeesofsim during SP analysis `SP1'.
Port or Term number 2 is missing. Check port numbering.
故障原因: 工程里面有TermG1,G3,跳过了 G2;
解决方法:将TermG3替换为 TermG2;