天天看点

Radware 8016风扇告警

    机房巡检,两台Radware 8016面板上的FAN只指示灯亮红灯。如何确认是否是风扇硬件故障?

一、开启告警日志实时弹出

#manage terminal traps-output set 2(或on)

HNCS-PC-IDC-SSL02-8018#24-11-2014 09:31:47 WARNING Fan failure was detected. 1 fan is not operational

二、开启日志记录

#manage trap-logging status set 1        /*开启日志记录

#manage trap-logging file-size set 1000

#manage trap-logging view-log              /*查看日志

#manage trap-logging clear-log              /*清除日志

HNCS-PC-IDC-SSL02-8018#manage trap-logging view-log

14452           warning         Fan failure     24-11-2014      1.3.6.1.4.1.89.

                                            was detected.   04:51:47        7             

                                            1 fan is not                                   

                                            operational 

三、查看风扇的工作状态

#system internal fans                                            

继续阅读