laitimes

The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

author:CET CLP Technology

In the face of the needs of small and medium-sized energy-consuming groups and park energy consumption monitoring and analysis, CET has launched a standardized solution product "CET-6605 Smart Energy Management All-in-One Machine", striving to provide target customers with localized energy management solutions with efficient deployment and easy operation and maintenance with high efficiency and high quality.

The CET-6605 smart energy management all-in-one machine integrates standard power monitoring and rich energy consumption management functions in a hardware and software integration manner, providing customers with efficient deployment and easy operation and maintenance of localized energy management solutions for factories, smart parks and other customers.

The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

Organizational chart

  • The CET-6605 smart energy management all-in-one machine is deployment-free and light debugging, supports local LAN operation, and also supports LAN operation at the same time, and the system can be synchronized through the edge communication server to achieve cloud-edge synergy.
  • Support third-party system/data docking.
  • As a standardized solution product under the framework of our cloud SaaS service product "Cloud Comprehensive Energy", the CET-6605 smart energy management all-in-one machine supports flexible access and expansion within the scope of its standardized function package to realize the application possibilities of various scenarios, such as power operation and maintenance functions, power quality functions, etc.

(1) Power monitoring function

(1) Real-time monitoring and management configuration

  • The electrical main wiring diagram of the substation and distribution system is displayed, and the full power parameters and the status of the switch circuit breaker are monitored and visualized in real time;
  • Based on the plane of the high and low voltage switchgear, the data such as full power, switching status information, temperature and humidity, and power data can be visualized in real time.
  • On-line monitoring of dynamic ring parameters of substation/distribution room, early warning of overrun; • Real-time monitoring of the operating status and energy-using parameters of important energy-using equipment/systems;
  • Custom custom configuration mode, which can support more custom application scenarios to display effect drawing.
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(2) Event push management

  • Events can be pushed through a web browser, and event-related information can be viewed.
  • Support notification of push platform events through APP/WeChat applet, and timely inform APP users/maintenance personnel to deal with abnormalities;
  • Event filtering is supported, which is convenient for categorical query and query by importance level.
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(3) Data analysis and inquiry

  • Real-time and historical data query and log management query of equipment within the scope of authority;
  • Support curves, tables and other styles of data display, support comparative analysis and export;
  • Support fault waveform analysis; • Log management function, which records every operation of the platform in detail.
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(4) Report inquiry

  • Users can customize the report, and the report time and format can be customized and configured according to actual needs.
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(2) Energy consumption management function

(1) Multi-dimensional data online supervision

  • You can set up a global project overview and set project dashboards in different projects
  • It supports energy consumption queries in different dimensions (time, space, and sub-items), and year-on-year, month-on-month, and energy-using region ranking statistics
  • It supports queries at different times, and can be queried by day, month, and year, and supports data export into report form
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(2) Time-sharing energy consumption data statistics

  • It supports automatic summary calculation of time-sharing energy metering, and supports flexible time-sharing scheme settings
  • The data can be exported to the form of a report, and the energy cost can be calculated according to the time-sharing energy consumption
  • It supports rate setting, as well as the setting and binding of multi-costing schemes
  • Support the financial accounting of energy projects
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(3) Energy consumption cost accounting analysis

  • It supports the display of comprehensive cost trends, including comprehensive cost overview, classification cost proportion, and regional cost proportion
  • Support cost accounting in each region, and calculate energy cost and unit energy consumption cost according to different time dimensions
  • Support different rate settings, support time-sharing rate settings
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

(4) Balance analysis of energy efficiency index and energy flow direction

  • Support the input and analysis of yield data
  • Supports benchmarking and analysis of energy efficiency KPI configurations
  • Support energy flow analysis, control energy flow direction, and the proportion of energy at each node
The CET-6605 smart energy management all-in-one machine can quickly realize new energy management solutions

In the actual application scenario, the power distribution room of a technology company needs to visualize and analyze energy consumption data, and needs to build a set of energy consumption management system in the local environment, with about 150 terminal meters. After the project was implemented, it took less than two days to complete the commissioning of the underlying equipment and the deployment and interface configuration of the smart energy management all-in-one machine, and complete the delivery, ensuring the safe and stable operation of the energy management system in the actual operation process.

For more information, click the "link" to consult CET's exclusive customer service to obtain information! Welcome to @CET CLP Technology.

Read on