There are 6 information systems involved in housing construction that need to be included in the application of the project's smart management platform or provide data docking, namely the information network system, the information guidance and release system, the smart toilet guidance system, the project's security system, the service intelligent lighting control system, and the project's building energy consumption monitoring and management system. It is necessary to provide relevant docking interfaces to the software system according to the requirements of the software system during the housing construction process of the project.

1. Information network system. It is necessary to ensure that all indoor and outdoor network systems are normal, and all network devices can be connected and interconnected. At the same time, it is interoperable with Shandong high-speed monitoring network and service development group network and can access the Internet.

2. Information guidance and release system. The project management platform needs to release the display content and read the equipment status of the touch screen query machine, hall LCD screen, and entrance and exit LED bar display, and need to provide the editing and release of the touch screen query machine, the hall LCD screen, the entrance and exit LED bar display and other display equipment, and the relevant equipment control instructions or docking protocols, SDKs, etc. At least or meet the following requirements:

(1) Touch screen inquiry machine

The touch screen inquiry machine needs to be connected to the network of this project, and it is recommended that the device adopt Android operating system and support software installation. It also has a web browser and can access designated websites.

(2) LCD screen in the lobby

The LCD screen in the lobby needs to support software installation, have a terminal browser, and can access the designated website.

(3) LED bar display at the entrance

The entrance and exit LED strip display needs to have the following functions and provide relevant interfaces.

serial number The name of the interface Field information
1 API for obtaining and displaying device information playlists At a minimum: playback sequence number, content
2 Obtain the interface to display the current playback content of the device At a minimum, it includes: the content number, and the specific content to be played
3 Publish or modify information APIs At a minimum, it includes: playback order, specific content, font color, font size, font type, font spacing, scrolling speed, dwell time, and screen entry mode
4 Delete the information interface At a minimum, it should include the playback sequence number or the ID of the corresponding information
5 API for obtaining the current running status of the device At a minimum: Operational status (normal, abnormal)

3. Smart toilet guidance system. The smart toilet guidance system requires the housing builder to independently purchase and arrange the corresponding hardware and software subsystems, independently complete all the functions of the smart toilet system according to the requirements of the construction drawings, and at the same time support data docking with the project management platform, and provide an integrated interface of the smart toilet and guidance system.

The Smart Toilet Guidance System includes at least the following functions:

(1) It is composed of front-end sensing equipment, network transmission equipment, management leveling, and display equipment.

(2) Use front-end sensing equipment to detect temperature and humidity and nitrogen in the air in real time. Hydrogen concentration and PM2.5 value and other indices are transmitted to the management system through the transmission network system, and the deodorization equipment can be automatically started when the set value is exceeded.

(3) utilize the utilization of front-end sensing equipment to realize monitoring pit position whether there are people, through transmission equipment system transmission to management system, management system through real-time statistics pit use, by front-end display screen real-time display toilet situation, toilet environment information etc., provide the toilet guidance display of the network station.

(4) The system should provide a data interface to achieve system integration.

At least the following interfaces shall be provided for data docking with the project management platform:

serial number The name of the interface Field information
1 Perceptual information acquisition Provides temperature and humidity, nitrogen in the air. Hydrogen concentration and PM2.5 concentration
2 Get the device status Provides information about the running status of front-end sensing devices
3 Acquisition of pit information Provide pit location information and usage records.
4 Device control interface Control instructions are issued for controllable equipment such as deodorization

4. The security precaution system of the project. According to the construction drawing design, the security system of the project is divided into the corresponding video security monitoring system in the housing construction, requiring the use of video digital streaming media control and other functions (specific details of the construction drawing), requiring each project to deploy Shandong high-speed high-definition video surveillance system, all cameras access to Shandong high-speed high-definition video surveillance system, to achieve video soft solution, video wall control and other functions. All cameras need to support the Onvif protocol, and the decoder needs to provide the equipment brand, model, and test prototype at the end of July (the deployment of Shandong high-speed HD video surveillance system needs to be paid separately).

5. Service intelligent lighting control system. According to the requirements of the construction drawings, the smart lighting system should at least realize the functions of 365 astronomical clock timing control, independent control of site lighting, open interface, support the monitoring, data statistics and analysis of each loop, and have a data docking interface for data docking with the project management platform.

serial number The name of the interface Field information
1 Clock synchronization Astronomical clock correction clock
2 Records are controlled independently Time, control the content
3 Status Records Real-time parameters such as voltage and current per circuit
4 Remote control Support remote device control
5 Other controls The winning bidder deepens the status reading and equipment control of other functions after the design

6. Building energy consumption supervision system. It is necessary to complete the subsystem of the building energy consumption supervision system according to the requirements of the construction drawings, and connect with the project management system to provide the status of water, electricity, gas, cold and heat and other energy consumption monitoring equipment and the acquisition interface and docking protocol of real-time energy consumption data.

At least the following APIs must be provided:

serial number corresponding system The name of the interface Field information
1 Building energy consumption monitoring system Interface to get real-time electricity consumption data At a minimum: meter location, electricity consumption, type of electricity consumption (lighting sockets, air conditioning, power consumption, special electricity)
2 Get a real-time water data interface At least: water meter location, water consumption, water use type (domestic water, reclaimed water, fire water, greening water)
3 API to obtain real-time gas volume data At a minimum: the amount of gas
4 Obtain real-time hot and cold data interfaces At a minimum: hot and cold heat

7. Construction equipment monitoring system. It is necessary to complete the subsystem of the building equipment monitoring system according to the requirements of the construction drawings, and provide the communication interface and protocol with the project management system for obtaining various operating parameters of the equipment in the building, such as exhaust fans, water supply and drainage, and power transformation and distribution equipment.

At least the following APIs must be provided:

serial number corresponding system The name of the interface Field information
1 Building equipment monitoring system Obtain the operation data interface of exhaust fan and blower At a minimum: operating status (normal, abnormal), cumulative working hours, energy data (if any)
2 Interface to obtain the operating data of water supply and drainage equipment (submersible sewage pump). At a minimum: operating status (normal, abnormal), fault status, water level of the sump well, cumulative working hours, energy data (if any)
3 Obtain the operating data interface of the substation and distribution equipment At a minimum, it includes: voltage, current, power factor, power, frequency, switching state
4 Obtain the operating data interface of the multi-online air conditioner At a minimum, it includes: operating status (normal, abnormal), cumulative working hours, energy data
5 Obtain the operation data interface of domestic water supply equipment At a minimum, it includes: operating status (normal, abnormal), cumulative working hours, energy data

8. It is necessary to provide the acquisition method or data docking protocol of the passenger flow data of the face passenger flow cylindrical camera.

At least the following APIs must be provided:

serial number Corresponding device The name of the interface Field information
1 Face passenger flow barrel camera API for obtaining face recognition data At a minimum, include the camera's unique identifier, latitude and longitude, number of face recognitions, age range (if any), and other relevant information

Introduction to the latest boutique information

There are more than 5,700 documents in total, and it is recommended to get a set, which is definitely helpful!

The PPT scheme in the article was all given, a total of 457 PPT, 6 sets of complete drawings, 343 industry standard specifications and construction drawing sets, 60 word schemes, 20 construction organization designs, 23 bills of quantities (with reference prices), 196 drawings and materials, 141 VISIO tiles and topology diagrams, project management and construction plans, 84 practical excel sheets, bidding plans and construction organization design, etc.

Read on